Pitch Tilt Skew
Tilt requires SMART sw to read when the laser line no longer crosses both start and stop codes
Pitch will reduce read efficiency by effectively shortening the code and cell size at extremes of the scan line
Skew is needed and should be 10 to 15 degrees for a laser scanner
(and 20 to 45 for a vision device like the Lector620)
Pitch will reduce read efficiency by effectively shortening the code and cell size at extremes of the scan line
Skew is needed and should be 10 to 15 degrees for a laser scanner
(and 20 to 45 for a vision device like the Lector620)